TMC-7100 Marine CEMS
Application
With the global strict control of ship emission pollution, the International Maritime Organization (IMO) constantly puts forward and upgrades the emission restriction requirements to reduce the emissions of sulfide, nitrogen oxide, carbon dioxide and other pollutants. From January 1, 2020, the emission restriction order of version 0.5 in Annex VI of the International Convention for the prevention of ship pollution has been formally implemented. Except for the restricted waters, the allowable emission limit of sulfur compounds from ships sailing in global waters has been reduced from 3.5% of fuel sulfur to 0.5%. Therefore, some ships have installed exhaust gas cleaning system (EGCS) to meet the requirements of the Convention. The flue gas treated by EGCS must be installed with online continuous exhaust monitoring system (CEMS) to meet the requirements of IMO MEPC259 (68) guidelines and ensure the monitoring, recording and archiving of pollutant emission concentration.
TMC-7100 General Introduction
TMC-7100 measures the gas concentration upstream or downstream of the scrubber and transfers them to the vessel’s main control system. TMC-7100 system integrates Shimadzu URA209 NDIR analyzer, adopts internationally famous brand sampling probe, heated pipeline, condensers, sampling pump and marine air conditioner. Tailor-made modular design for the unique application of marine ships, is easy to install and maintain, and is suitable for long-term high temperature, high humidity and strong vibration environment. Meet the requirements of MEPC.259(68).
TMC-7100 consists of the following parts:
Sampling probe with auto back purging
Heated sample gas pipeline
EC conditioning system
Shimadzu NDIR analyzer
Integrated in painted SS cabinet with air conditioner
TMC-7100 Solution Benefit
Continuous measurement of SO2, CO2 (SO2/CO2 ratio) with proven URA209 NDIR analyzer, ensure the accuracy of SO2 test under the concentration range of 40 µmol/mol reliable
Can expand NOx and O2 monitoring module
Low maintenance due to auto-calibration and auto back purging
MARPOL referenced extractive gas sampling instruments
Friendly HMI, long-term & massive data storage, GPS positioning
RS485 communication, seamless connection with EGCS from different manufactures
TMC-7100 Core: Shimadzu URA209 NDIR Analyzer
High selective
Low Detection Limit
High measurement accuracy
Automatic calibration
Automatic SO2& CO2 test range switching
Flexible interface for remote maintenance
Economic
Stable
Heated Probe
Certified by DNV-GL Classification Society: No. TAA00002FW
Heated internal surface filtration, keep probe chamber free of dust
One-hand 90° rotation to replace the built-in filter, pops out without tools
Increased protection degree IP66 for easy commissioning and maintenance
Particularly suitable for use in high-vibration marine applications
115/230 V universal power supply
All connections are fully insulated, no cold spots

Cooler
Low wash out effects for SO2, NO2 etc. Complies with EN 15267-3
Pluggable heat exchanger with high thermal conductivity
Two-stage condensation to fully remove H2O
Unique constant cooling control system, dew point stability 0.1 °C
Integrated cooling temperature analog output, remote monitoring
Air Conditioner
Widely used for Marine application globally
Energy-efficient Blue e wall-mounted cooling units with integral e-Comfort controller and RiNano coating on the condenser as standard
External circuit IP 34; Internal circuit IP 54
Operation (environment): +10 °C...+55 °C; Setting range: +30 °C...+35 °C
0.85 kW, 230 V, 1~, 50/60 Hz, Sheet steel, WHD: 280 x 550 x 280 mm
Refrigerant: R134a; Quantity: 280 g; Global Warming Potential (GWP): 1430; CO₂ equivalent (CO₂e): 0.4 t

DNV GL Certificate


LR Certificate

BV Certificate

ABS Certificate

NK Certificate

TMC-7100 Specification
Measuring Principle | NDIR |
Measuring Components | SO2,CO2 |
Measuring Range | SO2:0-50/500ppm |
CO2:0-5%/15% |
Response Time | 4~7S |
Accuracy | 0.5% F.S. |
Zero Drift | <1% F.S. |
Span Drift | <2% F.S. |
Linearity Error | <1% F.S. |
Detection Limit | <1% F.S. |
Repeatability | <1% F.S. |
Auto-Calibration | Yes |
Sample Temperature | 190℃ |
Sample Dust Load | Max 1g/nm3 |
Heated Pipeline Temperature | 120℃~180℃ |
Cooler Temperature | 2~5℃(Control Accuracy ±0.1%) |
Pump Capacity | Max 400L/h |
Sample Gas Inlet | 1.0~1.5L/min |
Filter Accuracy | 0.1um |
Display | LCD |
Operation Temperature (Analyzer) | -5~55℃ |
Power | 220VAC, 2,000W~3,600W |
Weight | ~220Kg |
Cabinet Dimension | 1,350x460x600mm |
Storage & Transportation Temperature | -20℃~60℃ |